高级检索
当前位置: 首页 > 详情页

ROI for outlining an entire tumor is a reliable approach for quantification of lung cancer tumor vascular parameters using CT perfusion

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology, China-Japan Friendship Hospital, Beijing, People's Republic of China [2]Department of Medicine, School of Medicine, University of California, . San Diego, CA, USA
出处:
ISSN:

关键词: lung carcinoma position size tomography X-ray computed dynamic enhancement microvessel density

摘要:
Objective: To investigate the effect of position and size of tumor region of interest (ROI) on the estimation of lung cancer vascular parameters using 256-slice computed tomography (CT) perfusion. Methods: After institutional review board approval and written informed consent, 16 men and 11 women with lung cancer were enrolled in this CT perfusion study. Perfusion, blood volume, and peak enhancement were determined for 60 or 120 mm(2) circular ROIs placed at the edge, center, and around (outlining) the visible tumor. Average values were obtained by performing ROI analysis twice by the same observers without any procedural changes. Results: Perfusion, blood volume, and peak enhancement measurements were substantially higher at the edge than at the center for both 60 and 120 mm(2) ROIs (all P<0.05). Measurements varied substantially depending on the ROI size. Perfusion, blood volume, and peak enhancement for the ROIs outlining tumor were intermediate between those at the tumor edge and center. There were significant correlations between median values and interquartile ranges as follows; perfusion (12.51 [7.91-28.10] mL.min(-1).100 mL(-1)), blood volume (29.31 [21.82-37.65] mL.100 g(-1)), peak enhancement (12.93 [2.42-22.50]) for the ROIs outlining the tumor, and microvascular density ([19.43 +/- 8.78] vessels/0.74 mm(2)), respectively (r values were 0.732, 0.590, and 0.544 respectively, all P<0.05). Conclusion: Spatial and size selection of ROI significantly affects CT perfusion analysis. ROI outlining of entire tumor provides efficient and reliable measurements for clinical assessment of lung cancer using CT perfusion.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 4 区 医学
小类 | 4 区 生物工程与应用微生物 4 区 肿瘤学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 生物工程与应用微生物 4 区 肿瘤学
JCR分区:
出版当年[2014]版:
Q2 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Q3 ONCOLOGY
最新[2023]版:
Q3 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Q3 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2014版] 出版当年五年平均[2010-2014] 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者单位: [1]Department of Radiology, China-Japan Friendship Hospital, Beijing, People's Republic of China
通讯作者:
通讯机构: [1]Department of Radiology, China-Japan Friendship Hospital, Beijing, People's Republic of China [*1]Department of Radiology, China-Japan Friendship Hospital, Yinghua Dongjie, Chaoyang District, Beijing, 100029, People’s Republic of China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:817 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)