单位: [1]Affiliated Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing 100050, Peoples R China
出处:
ISSN:

关键词: X-ray computed tomography volume measurement ground-glass opacity nodule

摘要:
Rationale and Objectives. The purpose of this study was to evaluate the effect of various tube currents on the accuracy of volumetric measurements of ground-glass opacity (GGO) nodules using a chest phantom. Materials and Methods. A chest phantom containing 13 artificial GGO nodules with known volumes was scanned using a 64-slice computed tomographic scanner at different tube currents (30, 60, 90, 120, 150, 180, and 210 mA). Volumetric measurements were performed using software. The relative percentage error and the absolute percentage error between the volume measures on computed tomography and the reference-standard volumes were calculated. Correlations between the mean absolute percentage error and the mean attenuation of nodules and between the ratio of solid component and the mean attenuation of nodules were analyzed. Results. The relative percentage errors showed that there was substantial underestimation of nodule volumes at 30, 60, and 90 mA and substantial overestimation of volumes at 120, 150, 180, and 2 10 mA, but there was no statistically significant difference in absolute percentage errors (P = .876). Pearson's correlation coefficient of the mean absolute percentage errors of nodules on volumetric measurement versus the mean attenuation value of nodules showed a negative correlation, and the ratio of solid component to whole nodule versus the mean attenuation of nodules showed a positive correlation. Conclusion. Volume measurement is a promising method for the quantification of GGO nodule volume. It is important to know that different tube currents can affect the accuracy of volumetric measurements.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2008]版:
大类 | 4 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2007]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2007版] 出版当年五年平均[2003-2007] 出版前一年[2006版] 出版后一年[2008版]

第一作者:
第一作者单位: [1]Affiliated Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing 100050, Peoples R China
通讯作者:
通讯机构: [1]Affiliated Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing 100050, Peoples R China [*1]Affiliated Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, 95 YongAn Rd, Beijing 100050, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)