An evaluation of the Unyvero pneumonia system for rapid detection of microorganisms and resistance markers of lower respiratory infections-a multicenter prospective study on ICU patients

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]National Clinical Research Centre for Respiratory Diseases, China-Japan Friendship Hospital, Capital Medical University, Beijing, China [2]Department of Pulmonary and Critical Care Medicine, Centre for Respiratory Diseases, China-Japan Friendship Hospital, Beijing, China [3]Tsinghua University-Peking University Joint Centre for Life Sciences, Beijing, China
出处:
ISSN:

关键词: Multiplex PCR Lower respiratory infections BALF Microorganisms Antibiotic resistance

摘要:
Rapid diagnosis of microorganisms and antibiotic resistance is vital for the appropriate treatment of patients with lower respiratory infections, especially for patients in Intensive Care Unit. We conducted a multicenter prospective study to evaluate the ability of the Unyvero pneumonia system for rapid detection from bronchoalveolar lavage fluid (BALF) in China. Eighty-four patients with lower respiratory infections were enrolled, and their BALF samples were collected, and Unyvero, a rapid molecular diagnostic sample-to-answer solution based on multiple PCRs, was applied to detect 21 types of pathogens and 19 types of resistance markers, compared to a routine bacterial culture method. The overall concordance of Unyvero and routine culture was 69/84 (82.1%). Unyvero detected more microorganisms than routine culture (38.1% vs 27.4%, P<0.05) and reported multi-pathogens in more patients than routine culture (10.7% vs 2.4%, P=0.01). The overall sensitivity and specificity of Unyvero for bacteria detection were 84.0% and 98.0%. Besides, Unyvero showed a good performance for antibiotic-resistant bacteria, except Pseudomonas aeruginosa. The concordance was 87.5-100% for methicillin-resistant Staphylococcus aureus and carbapenem-resistant isolates but was only 20-33.3% for Pseudomonas aeruginosa. The high-level semi-quantitative signal intensity of microorganisms detected positive by Unyvero correlates well with positive bacterial cultures. For specimens that were exposed to antibiotic treatment, the Unyvero pneumonia system showed a high concordance with routine bacterial culture and performs well for the detection of antibiotic-resistant bacteria, especially, carbapenem-resistant Klebsiella pneumoniae. It shows promise in guiding the clinical use of antibiotics, such as ceftazidime/avibactam. However, the system needs improvement in detecting resistance markers of Pseudomonas aeruginosa.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 4 区 传染病学 4 区 微生物学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 传染病学 3 区 微生物学
JCR分区:
出版当年[2019]版:
Q2 INFECTIOUS DISEASES Q3 MICROBIOLOGY
最新[2023]版:
Q2 INFECTIOUS DISEASES Q2 MICROBIOLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2019版] 出版当年五年平均[2015-2019] 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]National Clinical Research Centre for Respiratory Diseases, China-Japan Friendship Hospital, Capital Medical University, Beijing, China [2]Department of Pulmonary and Critical Care Medicine, Centre for Respiratory Diseases, China-Japan Friendship Hospital, Beijing, China
通讯作者:
通讯机构: [1]National Clinical Research Centre for Respiratory Diseases, China-Japan Friendship Hospital, Capital Medical University, Beijing, China [2]Department of Pulmonary and Critical Care Medicine, Centre for Respiratory Diseases, China-Japan Friendship Hospital, Beijing, China [3]Tsinghua University-Peking University Joint Centre for Life Sciences, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)